Hydrophobic Polyurethane Grouting Material
1 / 4
Polyurethane Grout

Hydrophobic Polyurethane Grouting Material

Oil-soluble PU grout that foams rapidly on water contact — fast active leak stoppage with rigid closed-cell support.

Suitable Environment
  • Dripping or seeping water
  • Low-to-moderate water volume
  • Where rigid filling and support is required
01 / Features

Key Highlights

  • 01Reacts and foams rapidly upon water contact for instant water stoppage
  • 02High expansion ratio with strong cavity-filling capability
  • 03Forms a rigid closed-cell foam structure
  • 04High foam strength with no shrinkage after curing
  • 05Chemical-corrosion resistant once cured
  • 06Combines water sealing with structural support
02 / Applications

Application Scenarios

  • Basement seepage and leakage
  • Tunnel and underground passage leakage
  • Construction joint water stoppage
  • Pipe-through-wall sealing
  • Concrete crack water stoppage
03 / Specifications

Physical Properties

Type
Single component
State
Liquid
Color
Light yellow
Density
≥ 1.05 g/cm³
Packaging Form
Steel drum

Performance Indicators

  • Density≥ 1.05g/cm³
  • Viscosity≤ 1000mPa·s
  • Gel time≤ 800s
  • Non-volatile content≥ 80%
  • Foam expansion ratio≥ 1000%
  • Compressive strength≥ 15MPa
04 / Installation

Application Guide

  1. 01Confirm injection-port layout — locate cracks and plan port spacing
  2. 02Drill holes across the crack at 25–30 cm depth, intersecting at 45°
  3. 03Install packers and connect single-liquid high-pressure pump
  4. 04Inject from the lowest port upward, advancing as adjacent ports begin to discharge
  5. 05After 72 hours, QA-inspect ports for seepage; trim packers and finish surface with cement mortar
  6. 06Immediately flush all pump components with cleaning agent after grouting
  • Drill bore must intersect the crack — verify before injection
  • Use a single-component pump only; do not run on dual-liquid equipment
  • Hold pressure until material foams out of the adjacent port, then move on
  • Trim cured material flush and seal residual port openings with mortar
05 / Storage & Safety

Transport, Storage & Safety

Storage & Transport

Store and transport away from direct sunlight and rain. Keep away from open flame and heat sources. Storage temperature ≤ 40 °C, well-ventilated, do not invert containers.

Shelf Life

6 months from manufacture date under normal transport and storage conditions

Precautions
  • Operators must wear PPE; rinse with clean water and seek medical attention if material contacts skin or eyes
  • Use immediately after opening; dispose of residual material per regulation
  • Do not blend with other materials — contact Yifeng technical service for assistance