1 / 4
Epoxy Grout
High-Penetration Epoxy Resin Injection Grout
Two-component low-viscosity epoxy that penetrates fine structural cracks, restoring monolithic strength to load-bearing concrete.
Suitable Environment
- Dry environments
- Slightly damp environments
- Not recommended where active running water is present
01 / Features
Key Highlights
- 01Low viscosity for deep penetration into hairline cracks
- 02Strong adhesion to concrete substrates
- 03Forms a high-strength rigid structure on cure
- 04Non-foaming and non-shrinking
- 05Combined repair and structural reinforcement
02 / Applications
Application Scenarios
- Cracks in load-bearing structures
- Beam, column, and slab cracks
- Structural reinforcement projects
- Concrete structure repair
03 / Specifications
Physical Properties
- Type
- Two component (A:B = 2:1 by weight)
- State
- A: clear colorless liquid · B: dark brown clear liquid
- Color
- Per component
- Density
- ≥ 1.0 g/cm³
- Packaging Form
- 10 kg / steel drum · 10 L / drum
Performance Indicators
- Slurry density≥ 1.0g/cm³
- Initial viscosity (mixed)≤ 200mPa·s
- Workable time≥ 30min
- Compressive strength≥ 40MPa
- Tensile shear strength≥ 5.0MPa
- Tensile strength≥ 10MPa
- Bond strength (dry)≥ 3.0MPa
- Bond strength (wet)≥ 2.0MPa
- Permeability resistance≥ 1.0MPa
- Permeability ratio≥ 300%
04 / Installation
Application Guide
- 01Clean dust and debris from the crack surface; install packers and check seal
- 02Drill packer holes intersecting the crack at 25–30 cm depth, alternating 45° on either side
- 03Mix components A and B at 2:1 by weight; stir uniformly until homogeneous
- 04Inject with a single-liquid high-pressure pump; start from the lowest port, progress upward
- 05Retain pressure until slurry appears at the adjacent port, then move on; repeat sequentially
- 06After 24 hours, QA-inspect; remove packers and finish surface with cement mortar
- Do not use dual-liquid pumps — mix A + B externally and pump as a single liquid
- Mixing tools must be clean and dry; mix only the volume usable within working time
- Confirm injection bore intersects the crack before pumping
- Workable time is > 30 min — schedule batch sizes accordingly
05 / Storage & Safety
Transport, Storage & Safety
Storage & Transport
Non-flammable, non-explosive solvent-free formulation — transport by normal methods. Store sealed in a cool, dry place. Maximum storage temperature ≤ 40 °C.
Shelf Life
12 months from manufacture date under normal transport and storage conditions
Precautions
- Operators must wear PPE; rinse with clean water and seek medical attention on contact
- If site water inflow is high, perform leak stoppage with a hydrophobic PU grout first, then return for structural epoxy grouting
- Reaction is exothermic — over-mixing or excessive batch size can cause heat build-up; mix only what is needed
- Do not blend with other materials — contact Yifeng technical service for assistance
Related Products

Hydrophobic Polyurethane Grouting Material
Oil-soluble PU grout that foams rapidly on water contact — fast active leak stoppage with rigid closed-cell support.
View Details

Hydrophilic Polyurethane Grouting Material
Water-reactive PU grout that swells into a flexible elastic gel — ideal for long-term seeping cracks and movement joints.
View Details

Polyurea Grouting Material
Ultra-fast-cure elastomeric grouting material that bridges dynamic cracks and forms a high-durability elastic seal.
View Details